INSTRUCTIONMANUALFORTHEINSTALLER
Mainswitch(preparedbythecustomer)
Motorpump(ifnotbuiltin)
Whencarryingoutelectricconnections,pleasetakeinto
considerationallwarningsandindicationsprovidedin
thismanual.Furthermore,inordertoavoiddangerous
overheating, unwind the power cable completely.
Should the power rating of the installation site not
correspondtotheonestatedonthe machine plate,
changetheconnectionsontheheatingelementand
onthepowercableofthemachine,followingthewiring
diagramsenclosedinthishandbookand/orinsidethe
machine(ontherightside).
Theappliancecablesaremarkedasfollows:
-Appliancepowercable
-Motor-drivenpumpcable(ifnotbuiltin)
ConnectcableA–(Pict2)directlytothesingle-poleswitch(1-Pict2).
ConnectcableB-(Pict2)directlytothemotor-drivenpump(2-Pict2).
CableB(pict2)isnottobefoundonappliancesttedwithbuilt-inpump.
Heating element
connection
Power cable
connection
V400/3
N
R
Black
Red
Brown
V230/3
Black
Red
Brown
Phase
V230
V400/3 V230/3 V230
Black
Red
Brown
N
S
M
T
A
N
Neutral
N
R
Phase
N
S
M
T
A N
N = Black
A = Blue
M = Brown
F
Phase
N
N
A M
Neutral