INSTRUCTIONMANUALFORTHEINSTALLER
Theelectricheatingsystemoftheapplianceisalreadysetbythemanufacturertooperateatatemperature
ofintheboiler,correspondingtoboilerpressure.Boilerpressureisviewedonthepressure
gauge(4)situatedonthebaseoftheappliance.
Inordertoincreaseordecreasetheboilerpressure,itisnecessarytooperateontheelectricpressure
switch(Pict14)whichisinsidethemachine(ontherightside),asindicatedherebelow:
• Turntheadjustmentscrewanti-clockwisetoincrease
boilerpressure.
•
Turntheadjustmentscrewclockwisetodecreaseit.
Boilerpressure(atoperatingtemperature)isnormally
modied exclusively in order to adapt the machine
temperaturetotheparticular typeofcoffeeblendso
astoobtainthebestresultinthecup.
Hotwaterdeliveryforinfusionsissemiautomatic:
tostartorstopdelivery,pressthehotwaterdeliverybutton(6).
Pressthecupwarmeroperatingbutton(24)andcheckitsoperatingstatusthroughthelightingupofthe
LED(23)onthecontrolpanel.Toswitchitoff,pressthesamebutton.
008
ADJUSTMENT SCREW
PRESSURE SWITCH