INSTRUCTIONMANUALFORTHEINSTALLER
Whentheapplianceisswitchedon,theelectronicpartcarriesoutacheck;allsymbolsonthecontrolpanel
areswitchedonfromlefttoright.Attheendofthisstage,thesymbolforthetemperaturesettingwillstart
toashtoindicatethattheapplianceisheatingup.
Theelectricheatingsystemoftheapplianceisalreadysetbythemanufacturertoworkatinthe
boiler,correspondingtoboilerpressureandonethermicdifferential(∆T)of.Thetemperatureis
viewedonthecontrolpanel.Itisalsopossibletochecktheboilerpressureonthepressuregauge(4)on
theappliance.
Itispossibletodeactivatetheelectricheatingoftheheatingelementsbypressingthebutton
(32)ontheprogrammingpanel.Oncedeactivated,therelevantsymbol(34)onthecontrolpanelwill
switchofftoindicatethisstate.Toreactivatetheelectricheating,pressthebutton
(32)again:the
symbol(34)willswitchon.
Itcanbeusefultodeactivatetheelectricheatingsysteminappliancesequippedwithgassystem.
Theproceduresnecessarytochangetheoperatingtemperaturearelistedinthefollowingparagraph.
Holddownthebutton (40)ontheprogrammingpanelfor;thesymbolonthecontrolpanel
forthesettemperaturewillremainlitwhiletheothersymbolswillswitchoff.
Usethebuttons (37)or (38)tochangethesetting.
Pressthebutton (40)toquittheprogrammingfunction.
•
•
•