INSTRUCTIONMANUALFORTHEINSTALLER
Theelectricheatingsystemoftheapplianceisalreadysetbythemanufacturertooperateatatemperature
ofintheboiler,correspondingtoboilerpressure.Boilerpressureisviewedonthepressure
gauge(4)situatedonthebaseoftheappliance.
Inordertoincreaseordecreasetheboilerpressure,itisnecessarytooperateontheelectricpressure
switch(Pict15)whichisinsidethemachine(ontherightside),asindicatedherebelow:
• Turn the adjustment screw anti-clockwise to
increaseboilerpressure.
•
Turntheadjustmentscrewclockwisetodecreaseit.
Boilerpressure(atoperatingtemperature)isnormally
modiedexclusivelyinordertoadaptthemachinetemperaturetotheparticulartypeofcoffeeblendso
astoobtainthebestresultinthecup.
Holddownthebutton
ofthersttouchpadontheright(1stGROUP)foraboutuntil
allLEDsonthetouchpadlightup(21-20-19-18).
Withinfastenalterholder(11b)containingadoseofgroundcoffeetothegroup;putacup
belowthelterholderandpressthebutton“1shortcoffee”(25)onthecorrespondingtouchpad.The
LEDfortheselecteddose(21)willswitchofftoindicatethatthedoseisbeingset.
Whenthecoffeereachestherequireddose,pressthebutton“1shortcoffee”(25)againtostopthecoffee
deliveryandconrmtherequireddose.
Repeatthesameprocedurefortheotherbuttons(26-27-28)alwaysreferringtothersttouchpad.
008
ADJUSTMENT SCREW
PRESSURE SWITCH