23
· TERMINAL BOARD M4 (Inputs 14, 15, 16, 17, 18.19)
19 = Input COMMON.
16 = auxiliary AUX 1. N.O. contact serving for three functions depending on
the configuration set on the control board:
a) Using the mechanical key selector EV-MSEL for the selection of
the door work program (F01=ON) connect terminal 16 to terminal 3
of the mechanical selector.
b) If ET-DSEL digital programmer is present, the activation of the
AUX1 input causes the door to close and the Night lock function to
activate, by-passing ET-DSEL digital programmer setting.
c) If INTERLOCK operation is activated between two Label automatic
doors (F27=ON), the activation of the AUX1 input by-passes the
interlock function (see the “Interlock system” paragraph).
14 = STOP/INTERLOCK input. Input contact logic state can be selected as
N.O. or N.C. by ET-DSEL digital programmer (function F24).
The input can be used for three different purposes, according to the
configuration set on the control unit:
a) Stop command to stop door motion.
b) detection of the interlock signal to prevent the door from opening
when the interlock function is enabled (function F27=ON). In this
case the input must be configured as N.C..
c) connection of a door closing device allowing to forcibly close the
door when function F52 is set to ON. In this case the input must be
configured as N.C.
15 = LOCK1 input. N.O. contact. Closing the contact on the input activates
the output of the UR24 module if option A is selected on function F41 m
or F45 m (see «UR24 Module» paragraph).
17 = auxiliary AUX 2. N.O. Contact serving for two functions depending on
the configuration set on the control board:
a) Using the mechanical key selector EV-MSEL for the selection of
the door work program (F01=ON) connect terminal 17 to terminal 4
of the mechanical selector.
b) It can be used as a door opening command in all automatic door
work programs.
18 = input OPEN. Input contact logic state can be selected as N.O. or N.C.
by ET-DSEL digital programmer (function F23).
The activation allows opening the door of all operating programs.
· TERMINAL BOARD M5 (Inputs 10, 11, 12, 13)
10 = Input COMMON.
12 = INTERNAL RADAR input. N.O. contact.
Activation causes the door to open. It is not active when the program
selector is set to "ENTRY" or to "Night lock".
13 = EXTERNAL RADAR input. N.O. contact.
Activation causes the door to open. It is not active when the program
selector is set to "EXIT" or to "Night lock".
11 = START input. N.O. contact.
Activation causes the door to open in all work programs (if F38 = OFF).
The input is disabled when "NIGHT LOCK" program is selected
(if F38 = ON).
M5
COMMON
M4
START
COMMON
AUX1
AUX2
OPEN
INTERNAL RADAR
EXTERNAL RADAR
STOP/INTERLOCK
LOCK1