P01
Opening speed. Max. 0,8 m/s per leaf.
Increasing the value will increase speed during the opening cycle.
P02
Closing speed. Max. 0,6 m/s per leaf.
Increasing the value will increase speed during the closing cycle.
P03
Reduced opening distance during winter. Min. 20 cm/leaf.
Adjustment of the reduced opening space as percentage of the free passage.
P04
Motor thrust power
Adjustment of the motor thrust power during door movement. At maximum value the maximum motor thrust is obtained.
The automaon has a safety system that stops and reverses movement of the door if the power limit is exceeded.
P05
Open door pausing me in the automac work programs
Seng values range between 0 (closing immediately aer opening) and 30 seconds.
P06
Open door pausing me in the Night Lock work program
Seng values range between 0 (closing immediately aer opening) and 30 seconds.
At the value 0% (default value) the funcon is deacvated.
This parameter allows to set a pause me in Night Lock program higher than pause me set by parameter P5.
P07
Acceleraon ramp when opening
It sets the leaf acceleraon phase during the opening cycle start.
Increasing the value will increase the leaf starng acceleraon during the opening cycle.
P08
Deceleraon ramp when opening
It sets the leaf deceleraon phase of the door at the end of the opening cycle.
Increasing the value, a faster braking is achieved at the end of the opening cycle.
At the 0% value (recommended seng) the braking control is automac.
In this case the automac door needs some maneuvers to stabilize the deceleraon to the ideal value.
P09
Deceleraon starng distance when opening
Increasing the value will increase the distance from the end of the stroke during opening at which the leaf proceeds at slow speed unl
the end of the stroke.
P10
Deceleraon starng distance when closing
Increasing the value will increase the distance from the end of the stroke during closing at which the leaf proceeds at slow speed unl
the end of the stroke.
P11
Motor thrust power at the end of the closing cycle
It sets the thrust power in the last phase of the closing cycle; this allows the leaf to more easily close on the final ledge.
Increasing the value will increase the thrust power.
P12
Reacon me to the obstacle in closing
Adjustment of the pushing me against the obstacle during the closing cycle before the reversal of the movement.
Increasing the value increases the pushing me and decreases the sensivity.
P13
Reacon me to the obstacle during the slowing down phase in opening at slow speed
Adjustment of the pushing me against the obstacle during the opening cycle at slow speed before the reversal of the movement.
Increasing the value increases the pushing me and decreases the sensivity.
P14
Reacon me to the obstacle in opening
Adjustment of the pushing me against the obstacle during the opening cycle before the reversal of the movement.
Increasing the value increases the pushing me and decreases the sensivity.
P15
Thrust force in the presence of an obstacle or fricon of the door
Adjustment of the pushing force on the obstacle. Once the set limit is exceeded, the automaon reverses the movement.
Aer removing the obstacle, in the next cycle the door searches the mechanical stop automacally at slow speed.
P16
Wind stop when the door is closed
It sets the intensity of the contrast force exerted by the motor, should anyone aempt to forcibly open the door.
Increasing the value will increase the intensity of the force contrasng the aempt to open the leaves.
P17
Distance from the final closing ledge at which the door reopens if an obstacle is detected during the closing cycle
When decreasing this value to 0% the moon direcon will be reversed if an obstacle is detected up to 5mm from the final closed door ledge
Below this distance the door stops and doesn't reopen.
P18
Distance between the end of the leaf stroke during opening and the mechanical opening limit switch
Increasing the value will increase the distance between the leaf and the mechanical limit switch, with respect to the value stored during set-up.
Decreasing the value will decrease the distance between the leaf and the mechanical limit switch, with respect to the value stored during set-up.
P19
Waing me between 2 consecuve door crossing warning gongs
It sets the waing me elapsing between the gong buzzer acvaon as the person passes through the automac door to its reacvaon
as an other person passes, to prevent repeated consecuve gongs. Please refer to the "Gong funcon" paragraph.
P20
Start delay when opening with respect to acvaon of electric lock
It sets the me aer which the door opens, since the issuing of the opening command and the acvaon of the electric lock.
When the parameter is set to 0% the leaf starts as soon as the electric lock is acvated; when it is set to 100% the delay will be of 5