F44
Unused funcon
Mulple selecon funcon that allows to set the operang mode of the OUT2 output for the UR24E relay module.
A
B
Door crossing warning GONG. The gong funcon is a entry warning triggered by the acvaon of the closing safety sensor (that is the
sensor connected to the E.C.1 terminal, or to the E.C.2 terminal) while the automac door is being crossed.
Please refer to the "Gong funcon" paragraph.
C
Air blade, device generang a flow of cold or heated air to separate the outside temperature from the inside one.
The output acvates when the door opens and deacvates when the door closes.
D
Baery status. The acvaon of the output signals the damaged baery status.
E*
Door status. Blinking slowly while the door is opening, on when the door is open, blinking fast when the door is closing, off when the
door is closed.
F
Alarm warning.
It acvates for two seconds if the radar or the closing safety sensor are engaged while the door is closed in Night Lock mode.
G
Maintenance signal.
The output acvates when the door reaches the number of cycles set in the maintenance plan by potenometer P48.
H
Unused funcon
F48
Unused funcon
F49
Unused funcon
F50
Unused funcon
F51
Unused funcon
OFF*
Forced closing funcon inacve.
ON
Forced closing funcon acve.
When a N.C. contact is connected to the Stop/Interlock input (terminals 11-14), it allows to forcibly close the door at slow speed aer
the device acvaon. During this closing operaon all command and safety inputs are disabled.
Should the forced closing device sll be acve once the door is closed, the only way to open the door will be using a held command on
the OPEN input (manned mode).
OFF*
The internal and external radars are not acve during the closing operaon in the "night lock" work program.
ON
The internal and external radars are acve during the closing operaon in the "Night Lock" work program, causing the door reopen.
F54
Unused funcon
F55
Unused funcon
F56
Unused funcon
F57
Unused funcon
F58
Unused funcon
F59
Unused funcon
F60
Unused funcon
F61
Unused funcon
F62
Unused funcon
F63
Unused funcon
F64
Unused funcon
F65
Unused funcon
F66
Unused funcon
F67
Unused funcon
F68
Unused funcon
F69
Unused funcon
F70
Unused funcon
F71
Unused funcon
F72
Unused funcon
F73
Unused funcon
F74
Unused funcon
F75
Unused funcon
F76
Unused funcon
F77
Unused funcon
F78
Unused funcon
OFF*
Cyclic funcon inacve
ON
Cyclic funcon acve. It acvates the connuous door opening and closing cycle. It is only used for operaon or durability tests.
Movement direcon: the movement direcon of the door is detected automacally in the inial set-up cycle.
To reverse the opening direcon change the status of the funcon (e.g. from OFF to ON).
F79
F80
F45m
Mulple
selecon
funcon
F52
F53
FUNCTION
EXPLANATIONSTATUS
The output shows the status of the LOCK1 input of the ET-LOGIC-B control unit. Output active with contact closed, deactivate with open contact.
This function can be used to indicate the status of the electric lock and the leaf position when installing the electric lock with microswitch.
Please refer to the "Electric lock → Electric connection" paragraph.