42
F44
Unused funcon
Mulple selecon funcon that allows to set the operang mode of the OUT2 output for the UR24E relay module.
A
B
Door crossing warning GONG. The gong funcon is a entry warning triggered by the acvaon of the closing safety sensor (that is the
sensor connected to the E.C.1 terminal, or to the E.C.2 terminal) while the automac door is being crossed.
Please refer to the "Gong funcon" paragraph.
C
Air blade, device generang a flow of cold or heated air to separate the outside temperature from the inside one.
The output acvates when the door opens and deacvates when the door closes.
D
Baery status. The acvaon of the output signals the damaged baery status.
E*
Door status. Blinking slowly while the door is opening, on when the door is open, blinking fast when the door is closing, off when the
door is closed.
F
Alarm warning.
It acvates for two seconds if the radar or the closing safety sensor are engaged while the door is closed in Night Lock mode.
G
Maintenance signal.
The output acvates when the door reaches the number of cycles set in the maintenance plan by potenometer P48.
H
Unused funcon
F48
Unused funcon
F49
Unused funcon
F50
Unused funcon
F51
Unused funcon
OFF*
Forced closing funcon inacve.
ON
Forced closing funcon acve.
When a N.C. contact is connected to the Stop/Interlock input (terminals 11-14), it allows to forcibly close the door at slow speed aer
the device acvaon. During this closing operaon all command and safety inputs are disabled.
Should the forced closing device sll be acve once the door is closed, the only way to open the door will be using a held command on
the OPEN input (manned mode).
OFF*
The internal and external radars are not acve during the closing operaon in the "night lock" work program.
ON
The internal and external radars are acve during the closing operaon in the "Night Lock" work program, causing the door reopen.
F54
Unused funcon
F55
Unused funcon
F56
Unused funcon
F57
Unused funcon
F58
Unused funcon
F59
Unused funcon
F60
Unused funcon
F61
Unused funcon
F62
Unused funcon
F63
Unused funcon
F64
Unused funcon
F65
Unused funcon
F66
Unused funcon
F67
Unused funcon
F68
Unused funcon
F69
Unused funcon
F70
Unused funcon
F71
Unused funcon
F72
Unused funcon
F73
Unused funcon
F74
Unused funcon
F75
Unused funcon
F76
Unused funcon
F77
Unused funcon
F78
Unused funcon
OFF*
Cyclic funcon inacve
ON
Cyclic funcon acve. It acvates the connuous door opening and closing cycle. It is only used for operaon or durability tests.
Movement direcon: the movement direcon of the door is detected automacally in the inial set-up cycle.
To reverse the opening direcon change the status of the funcon (e.g. from OFF to ON).
F79
F80
F45m
Mulple
selecon
funcon
F52
F53
FUNCTION
EXPLANATIONSTATUS
The output shows the status of the LOCK1 input of the ET-LOGIC-B control unit. Output active with contact closed, deactivate with open contact.
This function can be used to indicate the status of the electric lock and the leaf position when installing the electric lock with microswitch.
Please refer to the "Electric lock → Electric connection" paragraph.