35
18) PROGRAM SELECTORS
The program selector allows the door user to select the operating mode.
Depending on one's preferences, the EV-MSEL mechanical key selector or the ET-DSEL digital programmer can be used.
Each program selector is described in details below.
ELECTRIC CONNECTIONS
Terminal 1 of EV-MSEL= to terminal 12 (Internal radar) of ETERNA 90 operator control unit.
Terminal 2 of EV-MSEL= to terminal 19 (Common) of ETERNA 90 operator control unit.
Terminal 3 of EV-MSEL= to terminal 16 (AUX 1) of ETERNA 90 operator control unit.
Terminal 4 of EV-MSEL= to terminal 17 (AUX 2) of ETERNA 90 operator control unit.
18.1) EV-MSEL MECHANICAL KEY SELECTOR
The operation of the 5-position mechanical key selector must be
enabled by setting the F01 function to ON on the ET-DSEL
programmer.
The key can be taken out of the selector when in any position in order to prevent the work program from undesired changes.3 ...>
MANUAL FREE DOOR PROGRAM
The manual free door program can be selected by means of the EV-MSEL selector to disable the automatic door automatic operation and to
let the operator manually move the leaves.
To enable the MANUAL FREE DOOR program in the desired position of the EV-MSEL mechanical selector, operate on the F36m function
combination on the ET-DSEL digital programmer (see para. "FUNCTIONS and SETTINGS").
Open door program
The door stops in complete opening position.
Reduced opening program during winter
To open the door partially
Bi-directional automatic program
The door automatically opens when each opening control activates.
Single-direction automatic program output only
To exclude the incoming detection on external radar input
Night lock program
The door can only be open by OPEN input or radio control if EN/RF1 radio receiver is installed.
OPERATING MODE
Insert and rotate the key in EV-MSEL selector to select the program desired.
and
= no active symbol
and
For any check on proper connection and operation of key mechanical selector, enter inputs diagnostics (see par. 14.6) to ensure
that different key positions correspond to activation of the following symbols: