32
16) STAND BY SWITCHING
The "stand by" function automatically switches off the electronic circuits of the control unit in the event of a power failure if the door is closed
in the Night lock program.
This function allows to minimize the consumption of the emergency battery to prevent it from discharging in a short time during a power
failure.
To enable the stand-by mode set function F10 = ON.
To open the door during stand-by mode, an input is provided between terminals 28 - 29 (Wake - GND) of the ET-LOGIC-B control unit, to
which must be connected a device with contact N.O.
A pulse on the Wake input allows the control unit to be turn on and to open the door at slow speed.