Connect the battery to connector J5 on control board ET-LOGIC-B.
To enable battery operation set function F06 = ON or SET S04 = ON from initial set-up.
Insert the battery charger into the J12 connector of the control unit ET-LOGIC-B.
The battery charger self-checks the battery charge level and displays a green and a red led (see table "LED SIGNALLING")
Operation
The ET-BAT90 device trips in case of mains power failure, allowing the ETERNA 90 operator to keep running.
The battery operating time depends on various factors, like the number of operations performed, the leaf weight, the connected external
devices , etc....
The charged battery can supply energy for approximately 15 continuous door opening/closing cycles.
IMPORTANT!
BATTERY TYPE: NiMH, 18V - 700mAh
! Periodically check battery efficiency
! To allow recharging batteries must always be connected to the
electronic control unit
! The equipment must be disconnected from the mains when removing
the batteries
! In case of replacement, always use genuine batteries.
! Replacement must be performed by qualified personnel
! Remove batteries from the equipment before its disposal
! Batteries contain polluting substances; therefore they must be
disposed of in accordance with the provisions of local regulations
!!
SIGNALLED EVENTS
BATTERY DISCONNECTED
BATTERY CHARGING
BATTERY CHARGED WITH MAINS VOLTAGE
BATTERY DISCHARGED
ON
ON
OFF
ON
OFF
OFF
OFF
LED SIGNALLING
SIGNALLED EVENTS
BLINKING
ON
WARNING!
RED LED DL6
GREEN LED DL7
BLINKING
31
BATTERY CHARGED WITHOUT MAINS VOLTAGE
BATTERY
18V
J5
-
+
BATTERY
to connector J12 of the control unit ET-LOGIC-B
BATTERY
CHARGER
ET-BAT