29
14.5) INPUT DIAGNOSTICS
ET-DSEL programmer allows checking the inputs status to ensure proper operation of all devices
connected with ETERNA 90 operator.
To enter "Inputs diagnostics" while the automatic door operating program is shown on display,
keep F2 button pressed for about 3 seconds.
The F3 button is only used in case the ET-DSEL programmer is connected to two ETERNA 90
operators and the symbol "1" is displayed at the top right if the inputs on operator 1 are being
viewed, or 2 if the viewed inputs are those of operator 2. Press F3 once to switch from 1 to 2 and
vice versa.
If the ET-DSEL programmer only manages a single operator the symbol "1" is displayed at the top
right.
The display shows the symbols of all operator inputs, with the relevant terminal number.
If an input is used, the corresponding symbol lights up with an arrow on a side.
14.4) FUNCTIONAL TESTING
Select door automatic operation by program selector.
Refer to “Program selectors” paragraph describing the two types of selector provided for to select the automatic door operating mode.
To start an opening manoeuvre, give a pulse to PS1 button (Start) on the ET-LOGIC-B board or engage the door opening devices.
Ensure that door opening and closing cycle is properly performed and that pulse organs and safety sensors operate; to adjust sensor
detection field, refer to the instructions delivered with the sensor.
The safety sensors must ensure that the leaf doesn't impact against any automatic door users (please comply with the provisions contained
in the regulations in force).
During door movement, intermittent signals could be heard as emitted by the buzzer to indicate that the limit power delivered by operator has
been reached, especially if leaf dimensions and weight are close to the limits allowed.
A short noise signal by the buzzer during start in opening is to be considered as normal, as the pick-up phase is the moment requiring
maximum force.
Adjust the thrust power by P04 parameter of ET-DSEL programmer (see . “Adjustment of parameters” paragraph).
To deactivate the buzzer noise signal when the power limit is reached, set up F40 function to ON (see “Functions setup”).
Check that the electric lock and the manual release are working properly.
If the operator is equipped with emergency battery, connect the battery connector to the BATTERY connector J5 on the ET-LOGIC-B control
unit (for detailed information about operation with the emergency battery please refer to para. “Emergency opening device”).
Safety on impact: placing an obstacle in front of the leaf while it is in motion will cause the leaf to stop and the motion direction to be reversed;
when performing the next cycle the leaf shall slow down in the point where it had come into contact with the obstacle.
To set up the available functions, refer to “Functions setup” paragraph.
To adjust the variable parameters, refer to “Adjustment of parameters” section.
REPEATING THE INITIAL SET-UP
Set-up operation must be repeated if one of the following conditions varies:
leaf weight, leaf stroke.
In this case select the PARTIAL option from «SET-UP MODE» to perform only the leaves stroke learning without changing the current
settings.
The buzzer noise signal for almost the entire stroke means that the leaf exceeds the limits allowed or frictions exist on the fixture; in
this case, the movements of automatic door are difficult and the opening/closing cycle could not be completed.
EXTERNAL
RADAR
INTERNAL
RADAR
START
OPEN
SAFETY
SENSOR FOR
CLOSING E.C.2
SAFETY
SENSOR FOR
OPENING E.O.1
AUX 1
SAFETY
SENSOR FOR
OPENING E.O.2
AUX 2
SAFETY
SENSOR FOR
CLOSING E.C.1
STOP/INTERLOCK
PRJ38 STOP PHOTOCELL
SPYCO
radio
control
LOCK 1