ENG
29
TOT (Time of Timer)
The CB100/Venus CB has 4 kinds time of timer function for TX. The display 1 mean time of timer
setting 1 minute. “TOT - On” will appear in the display with error beep sound to indicate that
the TOT has activated.
Scan stop control
The scan resume condition can be set as a pause(p5) or time scan (5/10/15).
When a signal disappears, scan resume after 5 sec. has passed regardless of the setting.
5/10/15: Scan paused for 5,10 or 5 sec. When a signal is detected, then resumes after that.
P5: Scan pauses until the signal disappears and then resumes after 5 sec.
Factory reset
If the radio’s display locks up or stops functioning properly, you might need to reset your radio.
Caution:
This procedure clears all the information you have stored in your radio.
Before you reset CB radio, try turning It off and on again,. If your CB radio is still not functioning
correctly you may need to reset the CB radio!
While holding the F/AF button, turn the CB radio on, “rESEt” will be displayed for 1 to 2 seconds.
The radio will then return to its factory default status.
Key lock
The Key lock feature allows you lock all of buttons on the radio except F/9/ASQ/PWR. So they
can’t be activated by wrong entries or accidentally. Press F and PTT. Use the same procedure