83-507-5002 Rev. A
32
Fig.4-4: J1 connector terminals and functions
141516
1718
19
2021
22232425
1
2
3
4
56
7
8
1011
12
13
9
Same ground
as P/S negative
sense (-S)
Isolated from
PS outputs,
same ground
as RS232/RS485
IMON
IPGM_RTN
VPGM_RTN
LOC/REM SIGNAL
IF_COM
IF_COM
ENA_IN
VMON
COM
CV/CC
IPGM
VPGM
LOC/
REM
P ENA_OUT
SO
PS_OK
CAUTION
To prevent ground loops and to maintain power supply isola-
tion when programming from J1, use an ungrounded pro-
gramming source.
WARNING
There is a potential shock hazard at the output when using a
power supply with rated output greater than 40V. Use wires
with minimum insulation rating equivalent to the maximum