FLUE EXHAUST INSTALLATION
ATTENTION: Use only air intake/ fume evacuation kits produced by Lamborghini Caloreclima.
CONCENTRIC FLUE PIPE
Fit the concentric elbow pipe positioning it on the desired direction and insert on it the sealing gasket. Then
fit the appropriate diaphragm (see table below).
Fit the air intake and flue exhaust pipes, observing the distances indicated on the installation scheme. The flue
pipe should slope slightly outward.
DOUBLE FLUE PIPE
Maximum length of CONCENTRIC FLUE PIPE 3 m
Maximum length of DOUBLE FLUE PIPE
(Intake + Exhaust) 20 m
Installing an elbow to connect the boiler to the chimney will cause a
drop in pressure.
The values set out in the table below indicate the necessary modifi-
cations to the length of the linear pipes.
CONCENTRIC FLUE PIPE
Diaphr.
Ø 78 mm
DOUBLE FLUE PIPE
length m
Max. length
0,5 ÷ 1 m
Over 1 m
max. 3 m
100
Max. 3000
220
Ø100
105
440
770
100 Max. 3000
160
330
SCARICO
Diaframma
aria
FLUE EXHAUST PIPE
Air diaphragm
1 m
0,6 m
0,5 m
0,3 m
ELBOW FITTED
AT 45°
ELBOW FITTED
AT 90°
TYPE OF INSTALLATION
CONCENTRIC FLUE PIPE
SEPARATE INTAKE/EXHAUST
** Air intake Ø 80
97
250
Diaphr.
Ø 87 mm
Diaphr.
Ø 47 mm
Diaphr.
Ø 50 mm
NO
0,5 ÷ 5 >5 ÷ 20 >20 ÷ 30