20
LSI 090 - Rev. 00 - Ed. 04/2018
6.8 UP FUNCTION
When the machine is operated in conditions which may considerably reduce its temperature, the boiler temperature can be increased
by 2°C by pressing the “+” button for approximately 3 seconds. The main display alternates the visualisation of the temperature with
the UP indication.
To deactivate the UP function, keep the “-” button pressed.
6.9 WASHING THE BOILER
Keep the “hot water delivery” button pressed per 3 seconds. The machine dispenses water from the wand for 2 minutes and then
resets the correct level of water in the boiler. During the washing of the boiler, the 3 central lines of the display are blinking.
To stop the boiler washing, press again the same button.
6.10 WASHING THE UNITS
Press and keep pressed any continuous dispensing button for 15 seconds. Then press the continuous dispensing button of one of the
dispensing units to activate the WASHING UNITS function that consists of alternating dispensing of 5 seconds and 5 seconds at stop.
Press the continuous dispensing button again of the concerned unit to nish the washing of the units.
To exit from the WASHING UNITS function, press and keep pressed the continuous dispensing button of one of the units for 5 seconds.