EasyManua.ls Logo

Leica DMi1 - User Manual

Leica DMi1
132 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Leica DMi1
Instructions for use
Gebrauchsanweisung
Mode d’emploi
MICROSYSTEMS
Leica Microsystems CMS GmbH. Handbuch, 11934049, Revision 1.0, 2014-04-15

Table of Contents

Other manuals for Leica DMi1

Questions and Answers

  • D
    Danny DavisAug 2, 2025
    Why I cannot bring the specimen into focus on my Leica Microscope?
    • J
      James PatrickAug 3, 2025
      If the specimen cannot be brought into focus, ensure you are using the correct immersion medium. Also, position the specimen with the cover slip facing down. Verify that the cover slip thickness is correct and meets the specifications for the objective being used.
  • T
    Todd PittmanAug 8, 2025
    Why is the camera's remote control not sensitive on Leica DMi1 Microscope?
    • B
      bryan01Aug 8, 2025
      The camera's remote control might be insensitive because the battery is low and needs replacement, or the IR reflection shield is not correctly positioned to reflect the IR signal to the sensor.
  • A
    Andrew SawyerAug 12, 2025
    Why is my Leica DMi1 image completely dark?
    • S
      Sara MillerAug 12, 2025
      The image might be completely dark because the LED in the built-in transmitted light illuminator could be defective, or the aperture diaphragm may not be open. If these steps don't resolve the issue, notify technical service.
  • L
    lindseysnowAug 18, 2025
    What to do if Leica DMi1 Microscope does not respond?
    • N
      Nicole JacksonAug 18, 2025
      If the Leica Microscope isn't responding, first ensure the AC outlet has power. Next, check that the stand is properly connected to the power supply and verify all cable connections.
  • J
    jryanAug 23, 2025
    How to fix unwanted stray light in Leica DMi1?
    • Z
      zharrisAug 23, 2025
      To address unwanted stray light, clean the specimen and neighboring lens surfaces.
  • T
    tyler23Aug 27, 2025
    Why phase contrast cannot be adjusted on Leica Microscope?
    • C
      Chad ManningAug 28, 2025
      Phase contrast cannot be adjusted if the specimen is too thick, too thin, or too brightly stained. It may also happen if refractive indexes of the mounting medium and specimen are identical, so that there is no phase jump, or the cover slip is not placed uniformly. Check that the correct light ring and slider are positioned, and open the aperture diaphragm completely.

Summary

Important Notes about this Instructions for use

Text symbols, pictograms and their meanings

Explains various symbols like WARNING, CAUTION, and other pictograms used in the manual.

Intended Purpose of Microscopes

Usage Guidelines and Restrictions

Defines intended use, contraindications, and reasonably foreseeable misuse.

Safety Notes

General and Electrical Safety

Covers general safety, electrical safety, grounding, and interference precautions.

Handling and Disposal Precautions

Advises caution for handling light sources, oil, chemicals, and proper disposal.

Type Labels and Compliance

Shows type labels and explains compliance marks.

Overview of the Instrument

Instrument Components

Describes key components: stand, illumination, eyepieces, objectives, focus, condenser, diaphragm.

Filters and Accessories

Details filters, C-mount, and object guides for microscope functionality.

Unpacking and Installation

Unpacking and Handling

Instructions for unpacking, handling, transport, and storage.

Installation Location and Environment

Specifies ideal conditions for installation and allowable ambient conditions.

Assembling the Microscope

Core Component Assembly

Instructions for assembling condensers, illumination column, eyepieces, and objectives.

Filter and Object Guide Installation

Instructions for inserting filters and attaching the object guide.

Electrical Connection

Guidelines for safe electrical connection during assembly.

Assembling the Options

Phase Contrast and Camera System

Steps for mounting phase contrast sliders, camera system, and IR shield.

Operation

Basic Setup and Focusing

Steps for basic transmitted light setup and specimen focusing.

Optical Adjustments

Covers tube/eyepiece adjustment, objectives, transmitted light, aperture diaphragm, and phase contrast.

Trouble Shooting

Stand and Illumination Issues

Problems and remedies for stand responsiveness and illumination issues.

Focus and Light Path Problems

Issues and solutions for focus, transmitted light, and phase contrast problems.

Care of the Microscope

Cleaning and Protection

Instructions for using dust covers and cleaning various parts.

Glass Surface and Objective Cleaning

Detailed guidance on cleaning glass surfaces and objectives.

Technical Description

Objective Specifications

Covers objective markings, color-coding, performance data, and field numbers.

Eyepiece, Tube, Condenser & Filter Specs

Details eyepiece, tube, condenser, and filter specifications.

EU Declaration of Conformity

Leica DMi1 Specifications

General IconGeneral
BrandLeica
ModelDMi1
CategoryMicroscope
LanguageEnglish

Related product manuals