Warning: this equipment is destined for use in industrial environments (Class
A apparatus). In residential, commercial and light industry environments, this
apparatus may generate radio interference: in this case, the user may be
required to operate while taking appropriate countermeasures.
The apparatus is sensitive to the presence of external electromagnetic elds,
which may reduce its performance.
Receiver test according to EN 302 066 v. 2.1.0
The unit has been tested according to the provision of the EN 302 066 v.
2.1.0. Specically, for the receiver test (that tests the inuence of an inter-
ferer signal to the device), the following performance criterion has been
used (see ETSI TS 103 361 v.1.1.1) .
Performance criterion: The difference D between the R
x
signal noise
(increased by an interferer) and the maximum input signal for the R
x
in the
linear region of operation.
Level of performance: D
min
> 30 dB
Technical Data 79