190TPS1200+
Technical Data
Humidity
Reflectors
Type Protection
TPS1200+ Max 95 % non condensing
The effects of condensation are to be effectively counter-
acted by periodically drying out the instrument.
Type Additive Constant
[mm]
ATR PS
Standard prism, GPR1 0.0 yes yes
Mini prism, GMP101 +17.5 yes yes
360° prism,
GRZ4 / GRZ122
+23.1 yes yes
360° Mini prism, GRZ101 +30.0 yes not recommended
Reflector tape S, M, L +34.4 yes no
Reflectorless +34.4 no no