Technical Data TPS1200+ 191
There are no special prisms required for ATR or for PS.
Electronic Guide
Light EGL
Automatic
corrections
The following automatic corrections are made:
Machine Automation
power prism, MPR122
For Machine
Control
purposes only!
+28.1 yes yes
Type Additive Constant
[mm]
ATR PS
Working range: 5 - 150 m
Positioning accuracy: 5 cm at 100 m
• Line of sight error • Vertical index error
• Tilting axis error • Standing axis tilt
• Earth curvature • Refraction
• Circle eccentricity • ATR zero point error
• Compensator index error