5.4101.8538.0 B
Troubleshooting 9-1
9 Troubleshooting
9.1 Troubleshooting Table
Symptom
Possible cause
Action
The machine does not start to
operate when the motor house
is deflected.
• The power cable is not
connected to the main
electrical supply.
• Connect the power cable to
the main electrical supply.
• There is no electricity from
the main electrical supply.
• Make sure there is power on
the main electrical supply.
• The motor has overheated
(thermal cut-out).
• The motor cable is not
connected to the control box
or the motor.
• One of the sensors is broken
or loose.
• Inverter error.
• Wait until the motor has
cooled down.
• Disconnect the power cable
from the main wall socket,
wait for a few seconds and
reconnect.
• Replace or fasten the motor
cable.
• Replace or fasten the sensor.
• If the problem remains, call
your local Lely service
provider.
The brush does not switch
direction.
• Examine LED activation lights
on sensor
• Disconnect the power cable
from the main wall socket
wait a few seconds and
reconnect.
• If the problem remains, call
your local Lely service
provider.
The brush does not stop.
• The controller does not
switch to standby.
• One of the sensors is broken
or loose.
• Examine LED activation lights
on the sensors.
• Disconnect the power cable
from the main wall socket,
wait a few seconds and
reconnect.
• If needed fasten the sensor at
2 mm distance from motor
house ring.
in n o vato rs in ag ric u lt u re