Troubleshooting 9-1
9 Troubleshooting
9.1 Troubleshooting Table
Symptom
Possible cause
Action
The machine does not start to
operate when the motor house
is deflected.
The power cable is not
connected to the main
electrical supply.
Connect the power cable to
the main electrical supply.
There is no electricity from
the main electrical supply.
Make sure there is power on
the main electrical supply.
The motor has overheated
(thermal cut-out).
The motor cable is not
connected to the control box
or the motor.
One of the sensors is broken
or loose.
Inverter error.
Wait until the motor has
cooled down.
Disconnect the power cable
from the main wall socket,
wait for a few seconds and
reconnect.
Replace or fasten the motor
cable.
Replace or fasten the sensor.
If the problem remains, call
your local Lely service
provider.
The brush does not switch
direction.
Examine LED activation lights
on sensor
Disconnect the power cable
from the main wall socket
wait a few seconds and
reconnect.
If the problem remains, call
your local Lely service
provider.
The brush does not stop.
The controller does not
switch to standby.
One of the sensors is broken
or loose.
Examine LED activation lights
on the sensors.
Disconnect the power cable
from the main wall socket,
wait a few seconds and
reconnect.
If needed fasten the sensor at
2 mm distance from motor
house ring.