eNeRGy-IOM-2020.11-EN
47
WARNING:
electrical heater is connected to main power risk of electrical shock switch off the unit prior
to open this section
The electrical heaters are placed after the coil.
It is protected as standard against overheat via a high temperature overload protection.
There are three sizes available for each size of unit:
S: Standard heat
M: Medium heat
H: High heat
Unit
Description
Type of modulation
Capacity
Current
E014- E019
Standard
1 stage
36 kW
52
A
Medium
Triac
90 kW
129,9 A
High
Triac
108 kW
155,9 A
Unit
Description
Type of modulation
Capacity
Current
E22- E27
Standard
1 stage
54 kW
77,9
A
Medium
Triac
108 kW
155,9 A
High
Triac
144 kW
207,8 A