Lenovo Storage S3200/S2200 Setup Guide 55
When a temperature fault is reported, it must be remedied as quickly as possible to avoid system damage.
This can be done by warming or cooling the installation location.
When a power supply sensor goes out of range, the Fault/ID LED illuminates amber and an event is
logged to the event log.
Power supply module voltage sensors
Power supply voltage sensors ensure that an enclosure’s power supply voltage is within normal ranges.
There are three voltage sensors per power supply.
Table 20 Controller module temperature sensor descriptions
Description Normal operating
range
Warning operating
range
Critical operating
range
Shutdown values
CPU temperature 3C–88C0C–3C,
88C–90C
> 90C0C
100C
FPGA temperature 3C–97C0C–3C,
97C–100C
None 0C
105C
Onboard temperature 1 0C–70CNoneNoneNone
Onboard temperature 2 0C–70CNoneNoneNone
Onboard temperature 3
(Capacitor temperature)
0C–70CNoneNoneNone
CM temperature 5C–50C 5C,
50C
0C,
55C
None
Table 21 Power supply temperature sensor descriptions
Description Normal operating range
Power supply 1 temperature –10C–80C
Power supply 2 temperature –10C–80C
Table 22 Voltage sensor descriptions
Sensor Event/Fault LED condition
Power supply 1 voltage, 12V < 11.00V
> 13.00V
Power supply 1 voltage, 5V < 4.00V
> 6.00V
Power supply 1 voltage, 3.3V < 3.00V
> 3.80V

Table of Contents