EasyManua.ls Logo

Lenovo ThinkAgile HX Series - Replace a Chassis Fan

Lenovo ThinkAgile HX Series
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Lenovo Converged HX Series Hardware Replacement Guide
© Copyright Lenovo 2017
7
Replace a chassis fan
Failed or failing chassis fans can cause the system to overheat and shutdown. Replace a failed chassis fan as
soon as possible. A failed chassis fan is indicated by:
An error in XCC
An error in the Prism web console
Figure 6. Chassis fan
Note: It is possible to replace the chassis fan while the system is powered on, if the cable management arm is
in place. To replace a chassis fan:
1.
Pull the node chassis from the rack.
2.
Remove the top cover as described in the Removing the top cover procedure in the ThinkSystem
Information Center.
3.
Replace the chassis fan with the error LED on, as described in the Replacing a hot-swap fan procedure in
the ThinkSystem Information Center.
4.
Replace the top cover as described in the Replacing the top cover procedure in the ThinkSystem
Information Center.
5.
Push node chassis back into the rack.
6.
Verify that the chassis fan is successfully replaced:
Error LED for the replaced fan is off
Amber warning light on the node front panel is off
No error shown in XCC
No error shown in Prism