EasyManua.ls Logo

Lenovo ThinkAgile HX Series - Replace a Host Bus Adapter (HBA)

Lenovo ThinkAgile HX Series
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Lenovo Converged HX Series Hardware Replacement Guide
© Copyright Lenovo 2017
9
4.
Remove the top cover as described in the Removing the top cover procedure in the ThinkSystem
Information Center.
5.
Replace the defective LOM NIC as described in the LOM Adapter replacement procedure or replace one of
the PCIe NICs as described in the Riser card replacement and PCIe adapter replacement procedures in the
ThinkSystem Information Center.
6.
Replace the top cover as described in the Replacing the top cover procedure in the ThinkSystem
Information Center.
7.
Push the node chassis back into the rack and reconnect the cables as necessary. Power on the node.
8.
Start the node by following the hypervisor specific Node Start procedure described in the Nutanix Hardware
Replacement Documentation.
9.
Verify that the NIC has been successfully replaced:
Amber warning light on the node front panel is off.
All network ports are fully functional.
Replace a host bus adapter (HBA)
A node may be able to self-correct for other adapter card errors; however, a failed HBA can lead to system
degradation and should be quickly addressed.
Indications of a failed HBA card include:
If using VMware ESXi, vCenter Alarms or Hardware Status shows an alert
The Prism web console shows a message similar to LSI HBA card not detected
Slow disk performance or slow system performance
The hypervisor cannot detect SSDs and HDDs, or the red LEDs on the drives are illuminated
The CVM won't start because no storage controller resources are detected
The hypervisor or BIOS does not detect the HBA card
Figure 8. ThinkSystem 430-16i SAS/SATA 12Gb HBA

Related product manuals