2.FollowtheinstructionsonthescreentosetthevolumenameandRAIDlevel,selectharddiskdrives,the
stripsize(RAID1cannotbestriped),andthecapacity.
Note:Donotexceedthemaximumcapacity.
3.Whennishallthesettings,pressEnter.Awarningmessagewillbedisplayed.PressYtoconrm
yoursettingsandcreatethevolume.
DeletingtheRAIDvolume
ThissectionprovidesinstructionsonhowtodeletetheRAIDvolumebyusingtheIntelMatrixStorage
Managerprogram.
TodeletetheRAIDvolumebyusingtheIntelMatrixStorageManagerprogram,dothefollowing:
1.SelectDeleteRAIDVolumefromtheIntelMatrixStorageManagerprogrammainmenuandpressEnter.
TheDELETEVOLUMEMENUopens.
2.FollowtheinstructionsonthescreentoselecttheRAIDvolumeandpressDel.
3.PressYwhenpromptedtodeletetheRAIDvolume.
RebuildingtheRAIDvolume
Whenthereisafailingharddiskdriveinthevolume,youneedtoreplacetheharddiskdrive.Then,the
volumewillbeautomaticallyrebuilt.Therebuildingwillbeperformedintheoperationsystem.
Onboard1068ESASRAIDcontrollerCongurationUtilityprogram
ThissectionprovidessomebasicinstructionsonhowtoconguretheonboardSASRAIDusingtheonboard
1068ESASRAIDcontrollerCongurationUtilityprogram.
ConnectingtheminiSAScable
Yourservercomeswitha200mm(7.87inches)miniSAScablewithfourSASconnectorsandoneSGPIO
connector.TheSGPIOconnectorofthecableconnectstotheJ51connectoronthesystemboard;thefour
SASconnectorsofthecableconnecttothefourSASconnectorsonthesystemboard.
122ThinkServerRD230HardwareMaintenanceManual