•IftheonboardSATAandonboardSATAsoftwareRAIDarecongured,notethefollowing:
–TheSGPIOconnectorofthe4–portSATAcableinthechassisshouldbeconnectedtotheJ45
connectoronthesystemboard.See“Locatingpartsonthesystemboard”onpage29
.
–ThefunctionoftheAmberLED2isonlyavailableafteryouentertheoperatingsystem.
•IftheonboardSASandonboard1068ESASRAIDcontrollerarecongured,notethattheSGPIO
connectorofthe4–portmini-SAScableinthechassisshouldbeconnectedtotheJ51connectoronthe
systemboard.See“Locatingpartsonthesystemboardwithanonboard1068ESASRAID”onpage31.
Table5.HarddiskdriveLEDs
Description
GreenLED1
(bottom)AmberLED2(top)
Harddiskdriveisnotpresent.
OffOff
Harddiskdriveispresentbutisnotactive.
OnOff
Harddiskdriveispresentandactive.Blinking
Off
Serverisintheprocessoflocatingtheharddiskdrive.On
Blinking
RAIDhasfailed.
OffOn
Harddiskdriveisrebuilding.BlinkingBlinking
Note:Forsomemodels,theharddiskdrivestatusinformationmightbedifferentfromtheinformationlistedin
theabovetable.Fortheseservermodels,refertothefollowingtwotablesfortheharddiskdriveLEDstatus.
Table6.HarddiskdriveLEDsfortheonboardSATAandonboardSATAsoftwareRAIDcongurations(somemodels)
Description
GreenLED1
(bottom)AmberLED2(top)
Harddiskdriveisnotpresent.
OffOff
Harddiskdriveispresentbutisnotactive.
OnOff
Harddiskdriveispresentandactive.Blinking
Off
Serverisintheprocessoflocatingtheharddiskdrive.OnOff
RAIDhasfailed.
OnOff
Harddiskdriveisrebuilding.Blinking
Off
Table7.HarddiskdriveLEDsfortheadd-onSASRAIDadapterconguration(somemodels)
Description
GreenLED1
(bottom)AmberLED2(top)
Harddiskdriveisnotpresent.
OffOff
Harddiskdriveispresentbutisnotactive.
OnOff
Harddiskdriveispresentandactive.Blinking
Off
Serverisintheprocessoflocatingtheharddiskdrive.
BlinkingBlinking
RAIDhasfailed.
OffOn
Harddiskdriveisrebuilding.BlinkingBlinking
Chapter5.Locatingparts,controls,LEDs,andconnectors27