8.PositiontheM.2storagemoduleonthesystemboardsothattheplasticpinspassthroughthe
correspondingholesintheM.2storagemodule.Then,presstheM.2storagemoduledownwarduntil
itissecuredbythelatches.
Figure105.InstallingtheM.2storagemodule
9.Connectthe6-pinsignalcableoftheM.2storagemoduletotherear-backplanesignalconnector
onthesystemboard.Then,connecttheSATAsignalcableoftheM.2storagemoduletooneofthe
followingconnectors:
•TheSATAconnectorontheLenovoThinkServerRAID720ixAnyRAIDAdapterifoneisinstalled.See
“RAIDadapter”onpage32
.
•TheSATAconnector1(ports4–7)onthesystemboardifyourserveriswithoutbackplanesand
AnyRAIDadapters.See“Systemboardcomponents”onpage48.
Whattodonext:
•Toworkwithanotherpieceofhardware,gototheappropriatesection.
•Tocompletetheinstallation,goto“Completingthepartsreplacement”onpage206
.
RemovingtheM.2storagemodule
Attention:Donotopenyourserverorattemptanyrepairbeforereadingandunderstanding“Readthisfirst:safety
information”onpagevand“Guidelines”onpage73.
Beforeyoubegin,printalltherelatedinstructionsorensurethatyoucanviewthePDFversiononanother
computerforreference.
Notes:
•IfyouremovetheM.2storagemodule,youcannotinstallM.2storagedrivesintoyourserverforstorage.
•UseanydocumentationthatcomeswiththeM.2storagemoduleandfollowthoseinstructionsinaddition
totheinstructionsinthistopic.
ToremovetheM.2storagemodule,dothefollowing:
1.Removeallexternalmediafromthedrivesandturnoffallattacheddevicesandtheserver.Then,
disconnectallpowercordsfromelectricaloutletsanddisconnectallcablesthatareconnectedto
theserver.
2.Prepareyourserver.See“Removingorextendingtheserverfromtherackcabinet”onpage75.
3.Removetheservercover.See“Removingtheservercover”onpage75.
Chapter6.Replacinghardware133