If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the top cover,
or remove the server from the rack.
Watch the procedure. A video of this procedure is available from the following links:
https://www.youtube.com/playlist?list=PLYV5R7hVcs-C6QgmsUMRG6ul0bHzrGmsG
https://list.youku.com/albumlist/show/id_54461099
Procedure
Step 1. Make preparations for this task.
a. Remove the top cover (see “Remove the top cover” on page 214).
b. Remove the PCIe riser assembly in riser zone 1 (see “Remove the PCIe riser assembly from
zone 1” on page 158).
c. Remove the PCIe riser assembly in riser zone 2 (see “Remove the PCIe riser assembly from
zone 2” on page 158).
Step 2. Disconnect the cable from the system board.
Step 3. Grasp the switch, and pull to remove it from the seat.
Figure 62. Removing the intrusion switch
After this task is completed
Install a replacement unit (see “Install the intrusion switch” on page 146).
If you are instructed to return the component or optional device, follow all packaging instructions, and use
any packaging materials for shipping that are supplied to you.
Install the intrusion switch
Follow instructions in this section to install the intrusion switch.
About this task
146 ThinkSystem SR850 V2 Maintenance Manual