Appendix
8-9
L _^ONMObk
Code NoteName
C0150
*
Controller status word
(parameter channel) for:
Bit General structure 1xx1
Speed control
4xx1
Torque control
(
p
a
r
a
m
e
t
e
r
h
a
n
n
e
l
)
f
o
r
:
93XX general
93XX default setting
f
0 (free access) Actual parameter set
0= PS2/4active
1= PS1/3active
g
for
C0005 = 1xx1
C0005 = 4xx1
(
P
2
1
0
2
)
1 IMP (pulse inhibit)
0 = Pulses for power stage enabled
1 = Pulses for power stage inhibited
(P2102)
2 (free a ccess) I
max
(current limit reached)
0 = Current limit not reached
1 = Current limit reached
3 FREE 3
(free access)
4 (free access) RFG on = RFG off
(RFG input = RFG output)
0 = RFG in < > RFG out
1 = RFG on = RFG off
5 (free access) Q
min
(f
d
f
dQmin
)
0= Q
min
not active
1= Q
min
active
6 f
d
= 0 (act. frequency = 0)
0= f
d
<>0
1= f
d
=0
n = 0 (actual speed value = 0)
0 = n<>0
1= n=0
7 Ctrl. inhibit (controller inhibit)
0 = No controller inhibit
1 = Controller inhibit
8-11 Controller status
0 = Unit initialisation
1 = Switch-on inhibit
3 = Operation inhibited
6 = Operation enable
7 = Message active
8 = Active fault
9= Poweroff
12 Warning
0= Nowarning
1= Warning
13 Message
0= Nowarning
1= Warning
14 FREE 14 (free access)
15 (free acce ss) Ready for operation (no error, overvoltage or undervoltage)
0 = Not ready for operation
1 = Ready for operation
The status word contains the most important status information in compressed form.
On the following pages you will find the assignment of the freely combineable bits for the predefined signal configuration of
the controller.
LECOM format: VH