Configuration
7-28
48XX/49XXSHB0399
Signal flow Function
4900SStr125
C116/C11
7
I
A
Threshold
C244
ÜI
A
Ü
I
x
Threshold adjustable from 0 to 100% under C244
Hysteresis fixed, default setting: C244 = 10%
l
Purpose
Adjustable armature current monitoring
l
Output level = HIGH
4900SStr126
C 116/C 117I
F
Threshold
C245
ÜI
F
Ü
I
x
Threshold adjustable from 0 to 100% under C245
Hysteresis fixed
Default setting: C245 =10%
l
Purpose
Adjustable field current monitoring
l
Output level = HIGH
Info:
The hysteresis indicates range between the threshold or the window at which the
function is activated and the switch-off value at which is function is deactivated
again.