C310* Speed-dependent
current limitation
Limit value 1
100% 0.0 % {0.1 %} +100.0 % Valid for speed under C313 C310
must be higher than C311!
C311* Speed-dependent
current limitation
Limit value 2
100% 0.0 % {0.1 %} +100.0 % Valid for speed under C314 C311
must be smaller than C310!
C312* n0
Speed-dependent
current limitation
3000
rpm
0 rpm {1 rpm} 5000 rpm Actual speed threshold (activation of
current limitation), condition: n
1
>n
0
C313* n1
Speed-dependent
current limitation
4000
rpm
0 rpm {1 rpm} 5000 rpm Actual speed threshold for limit value 1,
condition: n
2
>n
1
>n
0
C314* n2
Speed-dependent
current limitation
5000
rpm
0 rpm {1 rpm} 5000 rpm Actual speed threshold for limit value 2,
condition: n
2
>n
1
>n
0