Installation
4-15
48XX/49XXSHB0399
Analog inputs
Ter minal Switch position Use Level Resolution
1, 2
2
S3
ON
OFF
Setpoint 2
with ground reference (factory
setting)
-10V...+10V 12 bit + sign
2
S3
ON
OFF
Setpoint 2
differential input
-10V...+10V 12 bit + sign
3, 4
12
34
S4
ON
OFF
Actual value -10V...+10V 12 bit + sign
1
2
34
S4
ON
OFF
Actual value -30V...+30V 12 bit + sign
1
2
34
S4
ON
OFF
Actual value -60V...+60V 12 bit + sign
12
34
S4
ON
OFF
Actual value (factory setting) -73V...+73V 12 bit + sign
12
3
4
S4
ON
OFF
Actual value -90V...+90V 12 bit + sign
1
2
3
4
S4
ON
OFF
Actual value -99V...+99V 12 bit + sign
12
3
4
S4
ON
OFF
Actual value -120V...+120V 12 bit + sign
1
2
3
4
S4
ON
OFF
Actual value -180V...+180V 12 bit + sign
5
S4
ON
OFF
Actual value
with ground reference
12 bit + sign
5
S4
ON
OFF
Actual value
differential input
1)
12 bit + sign
6 Setpoint 3 with ground reference -10V...+10V 12 bit + sign
7 Internal ground, GND
8
1
S3
ON
OFF
Setpoint 1,
Master voltage (factory setting)
-10V...+10V 12 bit + sign
1
S3
ON
OFF
Setpoint 1,
Master current
-20mA...+20mA
-20 mA...-4 mA
+4 mA...+20 mA
9 Voltage supply for +10V/7mA
10 Setpoint selection via potentiometer -10V/7mA