EasyManua.ls Logo

Lenze 4800 - Page 53

Lenze 4800
342 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
4-15
48XX/49XXSHB0399
Analog inputs
Ter minal Switch position Use Level Resolution
1, 2
2
S3
ON
OFF
Setpoint 2
with ground reference (factory
setting)
-10V...+10V 12 bit + sign
2
S3
ON
OFF
Setpoint 2
differential input
-10V...+10V 12 bit + sign
3, 4
12
34
S4
ON
OFF
Actual value -10V...+10V 12 bit + sign
1
2
34
S4
ON
OFF
Actual value -30V...+30V 12 bit + sign
1
2
34
S4
ON
OFF
Actual value -60V...+60V 12 bit + sign
12
34
S4
ON
OFF
Actual value (factory setting) -73V...+73V 12 bit + sign
12
3
4
S4
ON
OFF
Actual value -90V...+90V 12 bit + sign
1
2
3
4
S4
ON
OFF
Actual value -99V...+99V 12 bit + sign
12
3
4
S4
ON
OFF
Actual value -120V...+120V 12 bit + sign
1
2
3
4
S4
ON
OFF
Actual value -180V...+180V 12 bit + sign
5
S4
ON
OFF
Actual value
with ground reference
12 bit + sign
5
S4
ON
OFF
Actual value
differential input
1)
12 bit + sign
6 Setpoint 3 with ground reference -10V...+10V 12 bit + sign
7 Internal ground, GND
8
1
S3
ON
OFF
Setpoint 1,
Master voltage (factory setting)
-10V...+10V 12 bit + sign
1
S3
ON
OFF
Setpoint 1,
Master current
-20mA...+20mA
-20 mA...-4 mA
+4 mA...+20 mA
9 Voltage supply for +10V/7mA
10 Setpoint selection via potentiometer -10V/7mA
Show/Hide Bookmarks