EasyManua.ls Logo

Lenze 8104 - Fuses; Motor Choke

Lenze 8104
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
Technical description 8100_A
k
+
+
m
f.
o
4.1.2 FUSES
Replace defectivefuses only with the specifiedtype when the device isswitched off.
The device carries potential up to 30 seconds after mains disconnectionl
4.1.3 MOTOR CHOKE
A motor choke is only required for large motor cable lengths:
as of 100m for unscreened motor cables
as of 50m for screened motor cables
lenze
Type
L
I
part no.
a
b
c
d
e f
k
m n
mH A
mm mm mm mm mm mm mm mm mm
8101-02 9
5
359485 66 67 50 54 69 61 78 4.8 9
8103-04
5 9
323330 96
77
84 61 96 86 86 5.8 9
8105 3.5 14 323331 96 77 84 61 96 86 86 5.8 9
8106
1.6 17 323361 96 77 84 61
96 86 86 5.8
9
Types
8101 I 8102 I 8103 I 8104
8105 8106
Mains fuses F1 M12A FF25A FF30A
(internal)
Part no.
331 113
307 308 321 554
Type
Motor
Inductivity per
Part no.
current
100m/50m cab1e 1ength
8101 - 8106
up to 10 A
1.0 mH 357 869