14
Technical description8100_A
Brake resistors
R
I
Pn
Ohm kW
Part no.
HxWxD
mm
82 0 I 450 W 345 394 448 x 47 x 100
2*100 0
I 100 W 309 163 170 x 33 x 48
470 0
I 120 W 305 062 170 x 33 x 48
For these brake resistorsapplies:
- maximum permissible braking time:
- maximum permissible duty cycle:
15s
25%
Brake resistorsare not supplied with the inverter.
Overcurrent release
2000/200W
2x 309 163
4700/120W
305 062
820/450W
345 394
*) The setting of the overcurrent release results from the maximum permissible
brake current of the resistor (r.m.s. valuel.
Overcurrent release and base are not supplied with the inverter.
Base for thermal overcurrent release: Part no. 325 701
Warning: In ca se of mains overvoltage (>260 VI, the brake chopper may be
activated. When using resistors without overload protection, the
resistors may burn out. Therefore, only resistors with integrated or
external temperature surveillance may be used. Since the surface of the
brake resistors may heat up to 350°C, the resistors must be built into a
fire-proofhousing.
The brake chopper output isnot protected against short-circuits.
lenze
Overcurrent release
Setting
*)
part no.
0.5 A 325 692
1.0 A
325 693
2.3 A 325 695