Technical description8100_A
Bipolar set-value input. terminal 8
17
168K
r1":' ~J
@I 1+
Umaster
i master
Use:
Set-value 1
Input resistance:
a) 168 kn
b) 250 n for master current
(min. source voltage of the master
current generator for fdmax: 5V)
Parameter setting:
Configuration: C005
Setting: C025, C026, C027
Tir. Tif: C012, C013 and
C100, C101, C103
Set-value: C046, C172
Resolution: 13 bit (-10V...+10V)
*) Factory setting
+ 10V/-10V reference voltage. terminals 9, 10
Use: .
Supply voltage for set-value input
using potentiometer
Output current:
maximum 7mA
unipolar set value bipolar set value
lenze
Set-va1ue
input
COOS C034
Sl/4
0.. .10V*
-0- -0- OFF
0.. .2OmA -0- -0-
ON
4...20mA -0-
-1- ON
-10...+10V
-1- -0- OFF
-20...+20mA -1- -0- ON
;1:4...:t20mA
-1- -1- ON