8100 _A Technical description
63
lenze
Code level
PRG Parameter level
Factory
Customer
<===>
settings settings
GENERAL PARAMETERS
e068
Codes C068 and C069 contain information about the
controller status. They can only be read via the lECOM.
e069
interface.
C070GainPI-controller
xxx 0.01.. .300 0.01.. .1.00 {o.on
1.0
1.0 .. .10.0 {O.n
10.. .300
{n
____0..____________________
---------------------------------------------------------
_.------- ----------.
C071Responsetime
xxxx s 0.010.. .100s 0.01.. .1.00s {O.Ols}
0.10s
PI controller
1.0 . ..10.0s {0.1s}
10 .. .300s
{ls}
Whenentering 9999, the l-corrpment is switched off.
---..----------------------
---------------------------------------------------.-----
____oe_oe .-.--------
C074Influence xxx
X 0 ...100X 0.0 ...100X {O.IX}
O.OX
PI controller
C081Ratedmotorpower The rated motor power (nameplate) must be entered
Pmot [kWJ
to adapt the motor to the inverter, in order
to ensure a smooth running with low speeds.
-.-----------........-------..-.....----------.-..-...-..
-0- SH + PRG 0.18kW
-1- SH + PRG
0.25kW
-2- SH + PRG
0.37kW
-3- SH + PRG
0.55kW
-4- SH + PRG O.75kW
-5- SH + PRG 1.1kW
-6- SH + PRG
1.5kW
-7- SH + PRG
2.2kW
-8- SH + PRG 3.0kW
-9- SH + PRG 4.0kW
-....--------------.....--------.......---------...---_..
Change is only possible with controller inhibit.
* C093Controll er type
-xx
810x = Controller type
------------..-.......-----.....----------...............
only for LECOMinterface.
* C094User password
xxx
SH+ PRG 0...999
0
...-----------------....--------....-------..-.....--..-.
If 0 is set, no password is requested under COO.
C098Languge
-0- SH+ PRG Germsn
-0-
.-.-.----------------....------......----------------.--.
-1-
SH + PRG
Engl ish
--...------------------.-.-------...-.-.-----------------
-2- SH + PRG French
* C099Software version
-0- 81 6.0
APPLleATlON PARAMETERS
* C100preselection: Select the desired Ti time with C100, then set
Additional Ti time
the Ti time with e101 or e103.
(set-value 1)
..-------------...-----........--.-.------------..--..--.
-1- SH + PRG Acceleration Tir1 or Deceleration Tif1
-1-
..-------------....----.-......-----------------...------
-2- SH+ PRG Acceleration Tir2 or Deceleration Tif2
.-...-------.--...-----.-.......---------------....--....
....
.----------------...--------....---------------..........
-15 SH + PRG Acceleration Tir15 or Deceleration Tif15
---...------------------... ---------........--------.......--------.----....-.-..---
----_...- -----------