8.2.1.2 Sengs in the Siemens »TIA Portal«
Here, commissioning with the Siemens »TIA Portal« is described. Please note
that in the default seng of the Siemens, »TIA Portal« changes to network
parameters carried out previously by a Lenze engineering tool
(e. g. »EASY Starter«) may be overwrien.
1. Open the Net view in the device conguraon and drag the controller from the catalog to
the net view of the PROFINET.
2. Assign the inverter to the associated IO-Controller .
3. Mark the inverter and change to the device view.
4. Set the IP address and the staon name ("PROFINET device name") in the Properes.
See: 4Staon name and IP conguraon ^ 74
In order for the inverter to be idened via Ethernet when the IO controller is
switched o, it is necessary for the staon name and the IP conguraon to be
saved in the device with line voltage failure protecon via the separate entry
with the »EASY Starter«. 40x2022:003
See: 4Saving the parameter sengs ^ 23
5. Below the device designaon and the name of the device descripon le, the device view
shows the pre-assignment of the output process data words and input process data words.
Pre-assigned process data words can be changed in Slot 1.
6. Save the project in the engineering tool.
7. Load the conguraon into the IO-Controller.
8. Set the IO-Controller to RUN.
8.2.1.3 Device descripon le
The device descripon le must be installed in the engineering tool used for conguring the
network (e. g. Siemens »TIA Portal«).
•
Download of GSDML les
The name of the device descripon le is as follows:
"GSDML-V<x>.<zz>-Lenze-I<NNN>PN<Version>-<yyyy><mm><dd>.xml".
Wildcard Informaon
x Main version of the GSDML scheme used
zz One-digit or two-digit subversion of the GSDML scheme used
NNN Specicaon of the device designaon
Version First version of the soware that can be used with this GSDML.
yyyy Year of publicaon
in (mm) Month of publicaon
dd Day of publicaon
Dening the user data length
The conguraon is supported by 256 process data bytes (up to 64 slots).
Example of selecng the device descripon le:
•
Mixed_In_Out_Byte_0008 8 process data bytes (in and out direcon)
Conguring the network
PROFINET
Commissioning