Address Name Default seng Data type
0x2859:001 PROFINET monitoring: Watchdog elapsed Warning [2] U8
0x2859:002 PROFINET monitoring: Data exchange exited No response [0] U8
0x2859:003 PROFINET monitoring: Invalid conguraon Warning [2] U8
0x2859:004 PROFINET monitoring: Inialisaon error Warning [2] U8
0x2859:005 PROFINET monitoring: Invalid process data Warning [2] U8
0x285A:001 Diagnosc conguraon: Alarm supression 0x0000 U16
0x2D81:001 Life-diagnosis: Operang me x s (Read only) U32
0x2D81:002 Life-diagnosis: Power-on me x s (Read only) U32
0x2D81:004 Life-diagnosis: Main switching cycles - (Read only) U32
0x2D85:001 Fan diagnoscs: Status - (Read only) U8
0x2D85:002 Fan diagnoscs: Speed - (Read only) U32
0x5810:001 Applicaon diagnoscs: Applicaon state - (Read only) U8
0x5810:002 Applicaon diagnoscs: Used memory size - (Read only) U32
0x5850:001 Commands for EtherCAT system bus master: Kommunikaon neu
starten
No acon/no error [0] U16
0x5850:002 Commands for EtherCAT system bus master: Reset counters No acon/no error [0] U16
0x5851:001 EtherCAT master diagnosis: EtherCAT master state - (Read only) U16
0x5851:002 EtherCAT master diagnosis: EtherCAT master state summary - (Read only) U32
0x5851:003 EtherCAT master diagnosis: EtherCAT error - (Read only) U16
0x5851:004 EtherCAT master diagnosis: Bus scan match - (Read only) U8
0x5851:005 EtherCAT master diagnosis: Congured cycle me x us (Read only) U32
0x5851:006 EtherCAT master diagnosis: Connected slaves - (Read only) U16
0x5851:007 EtherCAT master diagnosis: Congured slaves - (Read only) U16
0x5851:008 EtherCAT master diagnosis: TX frame counter - (Read only) U32
0x5851:009 EtherCAT master diagnosis: Lost frame counter - (Read only) U32
0x5851:010 EtherCAT master diagnosis: Working counter error - (Read only) U32
0x5851:011 EtherCAT master diagnosis: DC slave sync deviaon limit x ns (Read only) U32
0x5851:012 EtherCAT master diagnosis: DC current deviaon x ns (Read only) I32
0x585C:001 EtherCAT master slave informaon: Slave address 0 I32
0x585C:002 EtherCAT master slave informaon: Vendor ID - (Read only) U32
0x585C:003 EtherCAT master slave informaon: Product code - (Read only) U32
0x585C:004 EtherCAT master slave informaon: Revision - (Read only) U32
0x585C:005 EtherCAT master slave informaon: Serial number - (Read only) U32
0x585C:006 EtherCAT master slave informaon: Auto-increment address - (Read only) I32
0x585C:007 EtherCAT master slave informaon: Fixed address - (Read only) U16
0x585C:008 EtherCAT master slave informaon: Second staon address - (Read only) U16
0x585C:010 EtherCAT master slave informaon: Master data link status - (Read only) U16
0x585C:011 EtherCAT master slave informaon: Master AL Status - (Read only) U16
0x585C:012 EtherCAT master slave informaon: Master RX Error Counter (Port 0-3) - (Read only) U64
0x585C:013 EtherCAT master slave informaon: Master Forwarded RX Error
Counter (Port 0-3)
- (Read only) U32
0x585C:014 EtherCAT master slave informaon: Master Processing Unit Error
Counter
- (Read only) U8
0x585C:015 EtherCAT master slave informaon: Master PDI Error Counter - (Read only) U8
0x585C:016 EtherCAT master slave informaon: Master Lost Link Counter (Port 0-3) - (Read only) U32
0x585C:017 EtherCAT master slave informaon: Master DC Sync 0 Period x ns (Read only) U32
0x585C:018 EtherCAT master slave informaon: Master DC Sync 1 Period x ns (Read only) U32
0x585D:001 EtherCAT master slave informaon: Master - Slave Address (AutoInc or
Fixed)
0 I32
0x585D:002 EtherCAT master slave informaon: Master VendorID - (Read only) U32
0x585D:003 EtherCAT master slave informaon: Master Product code - (Read only) U32
0x585D:004 EtherCAT master slave informaon: Master Revision - (Read only) U32
0x585D:005 EtherCAT master slave informaon: Master Serial number - (Read only) U32
0x585D:006 EtherCAT master slave informaon: Master Auto-increment address - (Read only) I32
0x585D:007 EtherCAT master slave informaon: Master Fixed address - (Read only) U16
Appendix