8.2.2.2 Suppress diagnosc messages to the IO controller
40x285A:001 serves to set which error response in the device suppresses the alarm message
to the IO-Controller.
Parameter
Address Name / seng range / [default seng] Informaon
0x285A:001 Diagnosc conguraon: Alarm supression
0x0000 ... [0x0000] ... 0xFFFF
Bit coded selecon of error responses which suppress the alarm
message to the IO controller.
Bit x = 1 = suppress alarm message.
In the default seng "0", an alarm message is displayed for all error
responses.
Bit 1 Warning
Bit 2 Warning locked
Bit 3 Trouble
Bit 4 Fault > Applicaon quick stop > Quick stop
8.2.3 Process data transfer
Process data serve to control the device.
The process data is transmied cyclically between the IO-Controller and the IO-Devices
parcipang in PROFINET.
The process data can be directly accessed by the IO controller. In the PLC, for instance, the
data is stored directly in the IO area.
The length of the process data is 1 ... 256 bytes (max. 64 slots) per direcon.
The process data is transmied 1 : 1 according to its sequence.
Conguring the network
PROFINET
Process data transfer