Commissioning
The most important codes for commissioning
EDK82MV222 DE/EN/FR 9.0
L
NOM
Code Possible settings IMPORTANT
No. Name Lenze Selection
C0002*
uSEr
Parameter set
management
-11-
0 0 Ready PAR1 ... PAR4:
z Parameter sets of the
controller
z PAR1 ... PAR4 also contain
parameters for
Standard-I/O,
Application-I/O,
AS interface or system
bus (CAN)
FPAR1:
z Module-specific
parameter set of the
fieldbus function modules
INTERBUS, PROFIBUS-DP,
LECOM-B,
DeviceNet/CANopen
z FPAR1 is saved in the
function module
Restorage of
default setting
1
Lenze setting Ö PAR1
Restorage of default setting
in the selected parameter set
2
Lenze setting Ö PAR2
3
Lenze setting Ö PAR3
4
Lenze setting Ö PAR4
31
Lenze setting Ö FPAR1
Restorage of default setting
in the fieldbus function
module
61
Lenze setting Ö PAR1 + FPAR1
Restorage of default setting
in the selected parameter set
of the controller and the
fieldbus function module
62
Lenze setting Ö PAR2 + FPAR1
63
Lenze setting Ö PAR3 + FPAR1
64
Lenze setting Ö PAR4 + FPAR1
C0002*
uSEr
(cont.)
Parameter set
transfer using
the keypad
Use the keypad to transfer
parameter sets to other
controllers.
During transfer the
parameters cannot be
accessed via other
channels!
Keypad Ö Controller
All available parameter sets
(PAR1 ... PAR4, and FPAR1)
are overwritten with the
corresponding keypad data
70 With function module
Application-I/O, INTERBUS,
PROFIBUS-DP, LECOM-B,
DeviceNet/CANopen
10
With all other function modules