Commissioning
The most important codes for commissioning
T
EDK82MV222 DE/EN/FR 9.0
NON
L
Code IMPORTANTPossible settings
No. SelectionLenzeName
C0002*
uSEr
(cont.)
Parameter set
transfer using
the keypad
Keypad Ö PAR1 (+ FPAR1)
Overwrite selected parameter
set and, if necessary, FPAR1
with the corresponding
keypad data
71 With function module
Application-I/O, INTERBUS,
PROFIBUS-DP, LECOM-B,
DeviceNet/CANopen
11
With all other function modules
Keypad Ö PAR2 (+ FPAR1)
72 With function module
Application-I/O, INTERBUS,
PROFIBUS-DP, LECOM-B,
DeviceNet/CANopen
12
With all other function modules
Keypad Ö PAR3 (+ FPAR1)
73 With function module
Application-I/O, INTERBUS,
PROFIBUS-DP, LECOM-B,
DeviceNet/CANopen
13
With all other function modules
Keypad Ö PAR4 (+ FPAR1)
74 With function module
Application-I/O, INTERBUS,
PROFIBUS-DP, LECOM-B,
DeviceNet/CANopen
14
With all other function modules
Controller Ö Keypad
All available parameter sets
(PAR1 ... PAR4, and FPAR1)
are copied to the keypad
80 With function module
Application-I/O, INTERBUS,
PROFIBUS-DP, LECOM-B,
DeviceNet/CANopen
20
With all other function modules
Keypad Ö Function module
Overwrite the
module-specific parameter
set FPAR1 only
40 Only with function module
INTERBUS, PROFIBUS-DP,
LECOM-B, DeviceNet/CANopen
Function module Ö Keypad
Copy the module-specific
parameter set FPAR1 only
50 Only with function module
INTERBUS, PROFIBUS-DP,
LECOM-B, DeviceNet/CANopen
efesotomasyon.com - Lenze