Loading...
System modules
DFIN_IO_DigitalFrequency (node number 21)
Inputs_DFIN
13
335
EDBCSXA064 EN 3.2
Signal setting
Finer resolutions can be realised by a downstream function block (e.g. L_CONV from the
LenzeDrive.lib) function library:
nIn_v nOut_v
L_CONV
nNumerator
nDenominator
DFIN_IO_DigitalFrequency
C0426
1
0
C0491
CTRL
C0421 C0427 C0420
C0419
X8
DI1
X6
1
0
0
TP/MP
-Ctrl
C0428 C0429
C0431
DFIN_nIn_v
DFIN_bTPReceived_b
DFIN_dnIncLastScan_p
ECSXA231
Fig. 13−23 SB "DFIN_IO_DigitalFrequency" with downstream FB "L_CONV" for the scaling
nOut_v + f[Hz] @
60
Number_of_incr._fromC0420
@
nNumerator
nDenominator
@
2
17
15000