EasyManuals Logo

Lenze ECS series User Manual

Lenze ECS series
483 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #335 background imageLoading...
Page #335 background image
System modules
DFIN_IO_DigitalFrequency (node number 21)
Inputs_DFIN
13
335
EDBCSXA064 EN 3.2
Signal setting
Finer resolutions can be realised by a downstream function block (e.g. L_CONV from the
LenzeDrive.lib) function library:
nIn_v nOut_v
L_CONV
nNumerator
nDenominator
DFIN_IO_DigitalFrequency
C0426
1
0
C0491
CTRL
C0421 C0427 C0420
C0419
X8
DI1
X6
1
0
0
TP/MP
-Ctrl
C0428 C0429
C0431
DFIN_nIn_v
DFIN_bTPReceived_b
DFIN_dnIncLastScan_p
ECSXA231
Fig. 13−23 SB "DFIN_IO_DigitalFrequency" with downstream FB "L_CONV" for the scaling
nOut_v + f[Hz] @
60
Number_of_incr._fromC0420
@
nNumerator
nDenominator
@
2
17
15000