Appendix
Code table
14
411
EDBCSXA064 EN 3.2
IMPORTANTPossible settingsCode
SelectionLenze/
{Appl.}
DesignationNo.
[C0540] X8 Signal out 2
Function of the digital frequency
output signals on X8 (DFOUT)
112
0 DFOUT in [%]
1 DFOUT in [rpm]
2 Encoder simulation + zero pulse ®
DFOUT
C0545 PH offset 0
Phase offset
340
0 {1 inc} 65535 1 revolution = 65535 increments
C0547 DIS: AN−IN
Analog signal on the input of the
DFOUT block
Read only
340
−199.99 {0.00 %} 199.99
C0549 DIS: DF−IN
Speed on the input of the DFOUT
block
Only display
340
−32767 {1 rpm} 32767
C0559 SD8 filter t 1
Filter time constant (SD8)
1 {1 ms} 200 Example:
If the setting is "10 ms", a
SD8−TRIP is actuated after 10 ms.
C0576 nErr tolerance 100
Tolerance window for the speed
system deviation referring to
n
max
100 % = lowest monitoring
sensitivity
226
0 {1 %} 100
C0577 Vp fld weak 0.100
Gain of the field weakening
controller (V
p
)
144
0.000 {0.001} 63.999
C0578 Tn fld weak 3.0
Integral−action time of the field
weakening controller (V
n
)
0.1 {0.1 ms} 6000.0
C0579 nErr response 3
Fault response − monitoring of
speed system deviation
226
0 TRIP
1 Message
2 Warning
3 Off
4 FAIL−QSP
C0580 Monit SD8 3
Fault response − monitoring of
SinCos signals at X8
225
0 TRIP
3 Off
C0581 MONIT EEr 0
Fault response − external fault
monitoring "ExternalFault" (EEr)
326
0 TRIP
1 Message
2 Warning
3 Off
4 FAIL−QSP