EasyManua.ls Logo

Lenze ECSEE040 - Page 150

Lenze ECSEE040
169 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
Code list
11
150
EDBCSXE040 EN 6.0
Parameter
C0444
Designation
Status of digital outputs
Data type: UNSIGNED_16
Index: 2413
dec
= 5E43
hex
Bit coded display of the digital output status
Display range (min. value | unit | max. value)
0x0000 0xFFFF
Bits (read only) Information
Bit 0 Trigger signal − +UG−relay
Bit 1 Trigger signal − −UG−relay
Bit 2 Trigger signal − IGBT
Bit 3 Trigger signal − thyristor
(LOW−active)
Bit 4 Internal signal ready for operation
(RDY)
Bit 4 = 1 (TRUE):
DC bus charged AND controller enable active (X6/DI2 =
HIGH or control word Ctrl1.Bit03 = 1)
Bit 5 Status of green LED (LOW−active)
Bit 6 Status of red LED (LOW−active)
Bit 7 Trigger signal − heatsink fan
(LOW−active)
Bit 8 IGBT gate driver reset (LOW−active)
Bit 9
Not assigned
...
Bit 15
Parameter
C0468
Designation
Function of power supply enable (X6/DI1)
Data type: INTEGER_32
Index: 24107
dec
= 5E2B
hex
Setting of power supply enable via terminal X6/DI1
Note: The parameters can only be changed if the controller is inhibited.
64
Selection list (Lenze setting printed in bold) Information
0 Mains disconnection (slow
discharge)
1 Mains disconnection and
TRIP−RESET
2 Mains disconnection and quick
discharge (short−circuit braking)
4 Mains disconnection, quick
discharge (short−circuit braking),
and TRIP−RESET
Parameter
C0469
Designation
Function of "STOP" keypad key for ECSxE
Data type: INTEGER_32
Index: 24106
dec
= 5E2A
hex
Setting of the "STOP" keypad key function of the ECSxE power supply module
Note: The parameters can only be changed if the controller is inhibited.
Selection list (Lenze setting printed in bold) Information
0 No function
1 Mains disconnection (slow
discharge)
2 Quick discharge (short−circuit
braking)

Table of Contents

Related product manuals