Troubleshooting and fault elimination
Fault analysis
Fault analysis via LECOM status words (C0150/C0155)
11
236
EDBCSXS064 EN 4.0
Code Possible settings IMPORTANT
No. Designation Lenze/
{Appl.}
Selection
C0155 Status word 2 0
Status word 2 (advanced status
word)
Display only
0 {1} 65535 Controller interprets information
as 16 bit (binary coded)
Bit 0 Active fault
Bit 1 M
max
reached
Bit 2 I
max
reached
Bit 3 Pulse inhibit(IMP)
Bit 4 Ready for operation (RDY)
Bit 5 Controller inhibit (CINH)
Bit 6 TRIP active
Bit 7 Initialisation
Bit 8 Motor direction of rotation (Cw/CCw)
Bit 9 Not assigned
Bit 10 Not assigned
Bit 11 Not assigned
Bit 12 Not assigned
Bit 13 Not assigned
Bit 14 Not assigned
Bit 15 Not assigned