Function library
CAN1Out
12
278
EDBCSXS064 EN 4.0
IMPORTANTPossible settingsCode
SelectionLenze/
{Appl.}
DesignationNo.
[C6211] Selection of the digital output
signals to the MotionBus (CAN)
1 CAN1Out−dig 1000 0 (FALSE, not assigned) Source for CAN1Out−Bit0 (bit 0)
276
2 CAN1Out−dig 1000 0 (FALSE, not assigned) Source for CAN1Out−Bit1 (bit 1)
3 CAN1Out−dig 1000 0 (FALSE, not assigned) Source for CAN1Out−Bit2 (bit 2)
4 CAN1Out−dig 1000 0 (FALSE, not assigned) Source for CAN1Out−Bit3 (bit 3)
5 CAN1Out−dig 1000 0 (FALSE, not assigned) Source for CAN1Out−Bit4 (bit 4)
6 CAN1Out−dig 1000 0 (FALSE, not assigned) Source for CAN1Out−Bit5 (bit 5)
7 CAN1Out−dig 1000 0 (FALSE, not assigned) Source for CAN1Out−Bit6 (bit 6)
8 CAN1Out−dig 1000 0 (FALSE, not assigned) Source for CAN1Out−Bit7 (bit 7)
9 CAN1Out−dig 1000 0 (FALSE, not assigned) Source for CAN1Out−Bit8 (bit 8)
10 CAN1Out−dig 1000 0 (FALSE, not assigned) Source for CAN1Out−Bit9 (bit 9)
11 CAN1Out−dig 1000 0 (FALSE, not assigned) Source for CAN1Out−Bit10 (bit
10)
12 CAN1Out−dig 1000 0 (FALSE, not assigned) Source for CAN1Out−Bit11 (bit
11)
13 CAN1Out−dig 1000 0 (FALSE, not assigned) Source for CAN1Out−Bit12 (bit
12)
14 CAN1Out−dig 1000 0 (FALSE, not assigned) Source for CAN1Out−Bit13 (bit
13)
15 CAN1Out−dig 1000 0 (FALSE, not assigned) Source for CAN1Out−Bit14 (bit
14)
16 CAN1Out−dig 1000 0 (FALSE, not assigned) Source for CAN1Out−Bit15 (bit
15)
17 CAN1Out−dig 1000 0 (FALSE, not assigned) Source for
CANSync−ResetSyncForInterpolat
ord
267
18 CAN1Out−dig 1000 0 (FALSE, not assigned) Source for CAN reset node
179
19 CAN1Out−dig 1000 0 (FALSE, not assigned) Source for
CAN−TxCan2Synchronized
20 CAN1Out−dig 1000 0 (FALSE, not assigned) Source for
CAN−TxCan3Synchronized
For possible signals see "selection list − digital
signals"
428
C6230 Display of the analog output
signals to the MotionBus (CAN)
−32768 {1} 32767
1 CAN−AnOut Output word CAN1Out−DctrlStat
276
2 CAN−AnOut Output word CAN1Out−W1
3 CAN−AnOut Output word CAN1Out−W2
4 CAN−AnOut Output word CAN1Out−W3
5 CAN−AnOut Output word CAN2Out−W0
285
6 CAN−AnOut Output word CAN2Out−W1
7 CAN−AnOut Output word CAN2Out−W2
8 CAN−AnOut Output word CAN2Out−W3
9 CAN−AnOut Output word CAN3Out−W0
291
10 CAN−AnOut Output word CAN3Out−W1
11 CAN−AnOut Output word CAN3Out−W2
12 CAN−AnOut Output word CAN3Out−W3

Table of Contents