EasyManua.ls Logo

Lenze ECSES Series - Page 284

Lenze ECSES Series
484 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function library
CAN2In
12
284
EDBCSXS064 EN 4.0
User data
Each of the eight bytes of received user data is assigned to different signal types. For this
reason, they can be evaluated —as required— as
ƒ digital signals (1 bit)
ƒ analog signals (16 bit)
ƒ phase signals (32 Bit)
in the axis module:
Byte Digital signals (1 bit) Analog signals (16 bit) Phase signals (32 Bit)
1, 2 CAN2In−Bit0
...
CAN2In−Bit15
CAN2In−W0
CAN2In−W0/W1
3, 4 CAN2In−Bit16
...
CAN2In−Bit31
CAN2In−W1
5, 6
CAN2In−W2
CAN2In−W2/W3
7, 8
CAN2In−W3
Note!
Via C0357 you can set the monitoring time (Lenze setting: 3000 ms) for data
reception. ( 198)

Table of Contents

Other manuals for Lenze ECSES Series

Related product manuals