Function library
CAN3In
12
290
EDBCSXS064 EN 4.0
User data
Each of the eight bytes of received user data is assigned to different signal types. For this
reason, they can be evaluated —as required— as
ƒ digital signals (1 bit)
ƒ analog signals (16 bit)
ƒ phase signals (32 Bit)
in the axis module:
Byte Digital signals (1 bit) Analog signals (16 bit) Phase signals (32 Bit)
1, 2 CAN3In−Bit0
...
CAN3In−Bit15
CAN3In−W0
CAN3In−W0/W1
3, 4 CAN3In−Bit16
...
CAN3In−Bit31
CAN3In−W1
5, 6
CAN3In−W2
CAN3In−W2/W3
7, 8
CAN3In−W3
Note!
Via C0357 you can set the monitoring time (Lenze setting: 3000 ms) for data
reception. ( 198)