EasyManua.ls Logo

Lenze ECSES Series - Page 295

Lenze ECSES Series
484 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function library
DCTRL
12
295
EDBCSXS064 EN 4.0
Codes
Code Possible settings IMPORTANT
No. Designation Lenze/
{Appl.}
Selection
C0135 Control word 0
System control word DCTRL
0 {1} 65535 Controller evaluates information
as 16 bits (binary−coded)
Bit 0 Not assigned
Bit 1 Not assigned
Bit 2 Not assigned
Bit 3 Quick stop (QSP)
Bit 4 Not assigned
Bit 5 Not assigned
Bit 6 Not assigned
Bit 7 Not assigned
Bit 8 Operation inhibit (DISABLE)
Bit 9 Controller inhibit (CINH)
Bit 10 TRIP−SET
Bit 11 TRIP−RESET
Bit 12 Not assigned
Bit 13 Not assigned
Bit 14 Not assigned
Bit 15 Not assigned
C0136 Control words
Hexadecimal value is bit−coded.
Read only
1 CTRLWORD
0 {hex} FFFF
Control word C0135
2 CTRLWORD CAN control word
3 CTRLWORD AIF control word
C0150 Status word 0
Device status word for
networking via automation
interface (AIF)
Read only
299
0 {1} 65535 Controller evaluates information
as 16 bits (binary−coded)
Bit 0 Not assigned
Bit 1 Pulse inhibit (IMP)
Bit2 Not assigned
Bit3 Not assigned
Bit4 Not assigned
Bit5 Not assigned
Bit 6 n = 0
Bit 7 Controller inhibit (CINH)
Bit 8 Device status bit 1
Bit 9 Device status bit 2
Bit10 Device status bit 3
Bit11 Device status bit 4
Bit12 Warning
Bit13 Message
Bit14 Not assigned
Bit15 Not assigned

Table of Contents