EasyManuals Logo

Lenze ECSES Series User Manual

Lenze ECSES Series
484 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #303 background imageLoading...
Page #303 background image
Function library
DFIN (master frequency input)
12
303
EDBCSXS064 EN 4.0
IMPORTANTPossible settingsCode
SelectionLenze/
{Appl.}
DesignationNo.
[C0491] X8 in/out 0
Function of X8
301
304
106
113
0 X8 is input
1 X8 is output
Configuring the master frequency input signal
Via C0427, you configure the master frequency input signal:
Configuration C0427 Track CW rotation CCW rotation
C0427 = 0 (2 phases)
B
B
A
A
Z
Z
a Track A leads by 90º
(positive value at DFIN_In_v)
Track A lags by 90º
(negative value at DFIN_In_v)
B ˘ ˘
Signal sequence with phase shift (CW
rotation)
C0427 = 1 (A = speed, B = direction)
B
B
A
A
Z
Z
a transmits the speed. transmits the speed
B = FALSE
(positive value at DFIN_In_v)
= TRUE
(negative value at DFIN_In_v)
Control of the direction of rotation via
track B
C0427 = 2 (A or B = speed or direction)
B
B
A
A
Z
Z
a transmits speed and
direction of rotation
(positive value at DFIN_In_v)
= FALSE
B = FALSE transmits speed and
direction of rotation
(negative value at DFIN_In_v)
Control of speed and direction of rotation
via track A or track B
Transfer function
DFIN_In_v + f[Hz] @
60
C0420
@
2
14
15000
Example:
ƒ Input frequency = 200 kHz
ƒ C0420 = 2048 (increments/revolution)
DFIN_In_v[rpm] + 200000Hz @
60
2048
+ 5859rpm

Table of Contents

Other manuals for Lenze ECSES Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze ECSES Series and is the answer not in the manual?

Lenze ECSES Series Specifications

General IconGeneral
BrandLenze
ModelECSES Series
CategoryControl Unit
LanguageEnglish

Related product manuals